๐ Inactivation of SARS coronavirus by means of povidone-iodine, physical conditions and chemical reagents
The efficacy of several povidone-iodine (PVP-I) products, a number of other chemical agents and various physical conditions were evaluated for their ability to inactivate the severe acute respiratory syndrome coronavirus (SARS-CoV). Treatment of SARS-CoV with PVP-I products for 2 min reduced the virus infectivity from 1.17 ร 106 TCID50/ml to below the detectable level. The efficacy of 70% ethanol was equivalent to that of PVP-I products. Fixation of SARS-CoV-infected Vero E6 cells with a fixative including formalin, glutaraldehyde, methanol and acetone for 5 min or longer eliminated all infectivity. Heating the virus at 56ยฐ C for 60 min or longer reduced the infectivity of the virus from 2.6 ร 107 to undetectable levels. Irradiation with ultraviolet light at 134ฮผW/cm 2 for 15 min reduced the infectivity from 3.8 ร 107 to 180 TCID50/ml; however, prolonged irradiation (60 min) failed to eliminate the remaining virus, leaving 18.8 TCID50/ml. ยฉ 2006 S. Karger AG, Basel.